Newly Arrival High Precision Power Distribution Cabinet UPS for Data Center
Often customer-oriented, and it’s our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for Newly Arrival High Precision Power Distribution Cabinet UPS for Data Center, Our ultimate goal is always to rank as a top brand and also to lead as a pioneer in our field. We are sure our productive experience in tool creation will get customer’s trust, Wish to co-operate and co-create an even better long term with you!
Often customer-oriented, and it’s our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for China Uninterruptible Power Supply and Data Center, We attained ISO9001 which provides solid foundation for our further development. Persisting in “High quality, Prompt Delivery, Competitive Price”, now we have established long-term cooperation with clients from both overseas and domestically and get new and old clients’ high comments. It is our great honor to meet your demands. We have been sincerely expecting your attention.
Features
Little Hint
1. In the warranty period the machine has a problem, please contact the sales staff, we will be responsible for customer service.
2. Exceed the warranty period, improper operation and man-made damage, we will still give help and support, we will provide spare parts at a cost price.
3. According to the customer’s needs, we can provide unconventional, but the cost may be slightly higher than the traditional machine.
Applications
Data processing center, The host system, Computer servers, Medical, Traffic, Electricity, IT, Industrial and other industries.
Factory Production Line
Packaging
Often customer-oriented, and it’s our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for Newly Arrival High Precision Power Distribution Cabinet UPS for Data Center, Our ultimate goal is always to rank as a top brand and also to lead as a pioneer in our field. We are sure our productive experience in tool creation will get customer’s trust, Wish to co-operate and co-create an even better long term with you!
Newly Arrival China Uninterruptible Power Supply and Data Center, We attained ISO9001 which provides solid foundation for our further development. Persisting in “High quality, Prompt Delivery, Competitive Price”, now we have established long-term cooperation with clients from both overseas and domestically and get new and old clients’ high comments. It is our great honor to meet your demands. We have been sincerely expecting your attention.
MODEL | BNT990-M | BNT9150/180-M | BNT9300-M | |
Rated Capacity | Cabinet Capacity | 20-90kVA / 20-90kW | 25-150kVA / 25-150kW 30-180kVA / 30-180kW | 30-300kVA / 30-300kW |
One Ppwer Module Capacity | 20kVA /20kW, 25kVA /25kW,30kVA /30kW | |||
MAX. Power Module NO. | 3 | 5/6 | 10 | |
INPUT | ||||
Main Input | Nominal Voltage(Vac) | 380/400/415 | ||
Voltage Range(Vac) | 138~485Vac;305~485Vac load,138~305Vac load | |||
Phase | 3-phase in / 3-phase out | |||
Nominal Frequency(Hz) | 40-70 | |||
Power Factor | ≥0.99 | |||
Harmonic Distortion (THDi) | ≤3% (100% load) | |||
Bypass Input | Nominal Voltage(Vac) | 380/400/415 | ||
Voltage Range(Vac) | 220 Vac:25%(+10%,+15%,+20%) | |||
230 Vac:20%(+10%,+15%) | ||||
240 Vac:15%(+10%);-45%(-10%,-20%,-30%) | ||||
Phase | 3-phase in / 3-phase out | |||
Power Walking In | YES | |||
Bypass Back Irrigation | YES | |||
Generator Access | YES | |||
OUTPUT | ||||
Voltage(Vac) | 380/400/415±1% | |||
Power factor | 1 | |||
Frequency(Hz) | AC Mode | ±1%/±2%/±4%/±5%/±10% | ||
Battery Mode | (50/60±0.1%)Hz | |||
Waveform | Pure Sinewave | |||
Admissible Crest Factor | 3:01 | |||
Harmonic Distortion(THDV) | ≤2% (100%Linear Load);≤3% (100%Non-linear Load) | |||
Transfer Time(ms) | 0 | |||
Efficiency(%) | 95.50% | |||
Overload Capability | 1 hour for 110%, 10 mins for 125%,1 min for 150%, 200ms for >150% | |||
BATTERY | ||||
Maximum Charging Current(A) | 18 | |||
Nominal Voltage | ±180V/±192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc | |||
(30/32/34/36/38/40/42/44/46/48/50 pcs) | ||||
ENVIRONMENT | ||||
Operating Temperature | 0℃~40℃ | |||
Storage Temperature | -25℃~55℃ | |||
Relative Humidity | 0~95% | |||
Altitude | < 1500m | |||
Noise Level(dB) | <58dB | <61dB | <68dB | |
PHYSICAL | ||||
Dimension (D x W x H) mm | UPS Cabinet | 600×850×1350 | 600×850×1350 600×850×1550 | 600×850×2000 |
Module | 440×620×86 | |||
Net Weight(kg) | UPS Cabinet | 140 | 155/170 | 290 |
Module | 21 |